If you can’t get the flame to light at all, and you’re sure the gas is on, there’s probably an obstruction in the pilot tube. If the flame lights and goes out when you release the gas control knob after holding it in for the recommended 20 to 30 seconds, that’s the sign of a thermocouple malfunction.Click to see full answer. In this regard, what does the thermocouple look like?The thermocouple looks like a piece of metal tubing smaller than a soda straw. To find it, first locate the gas control box. This is the box that the main gas line enters, where you turn the gas on in the furnace. The other end of the thermocouple sits in the flame of the pilot light.Also, how do you fix a bad thermocouple? A burned out or broken thermocouple should be replaced. To replace a thermocouple: Step 1: Unscrew the copper lead and the connection nut inside the threaded connection to the gas line. Step 2: Under the mounting bracket at the thermocouple tube, unscrew the bracket nut that holds the tube in place. Likewise, people ask, how long does a thermocouple last? Thermocouples can last several years, but they don’t typically last as long as the furnace itself. If the pilot remains lit, but the main furnace doesn’t stay lit, it’s time to replace the thermocouple. Replacement thermocouples are in stock at most hardware and home improvement stores.Can a thermocouple be cleaned?If the Thermocouple is faulty it will cause the unit to shut down. How to clean? Remove Thermocouple from pilot assembly, using steel wool or emery cloth to lightly clean the tip removing any soot or build up that might have accorded due to an improper pilot flame.